next up previous contents
Next: RUN control Up: SoftWare Previous: Data stream

data format

data file are now in ACSII file. The data format is like this.

1.
RUN summary file
This file will be made, when new sub run starts.
 
Table 4: Run header file
# discription type comment
000 Length int total length of this file
001 RUN # int  
002 Start event number int  
003 End event number int  
004 # of events int  
005 Start time(sec) int  
006 Start time(micro sec) int  
007 End time(sec) int  
008 End time(micro sec) int  
009 Trig. type/Detector status int bit pattern.
010 Trig. type/Detector status int bit pattern.
011 Trig. type/Detector status int bit pattern.
012 Trig. type/Detector status int bit pattern.
013 Trig. type/Detector status int bit pattern.
014 Trig. type/Detector status int bit pattern.
015 Delimiter int (-length)

At this component, The time is cpu time.
2.
event data
This is event by event data-format of each monitor.
last bit of Spill number is pedestal flag. If data is pedestal data, that bit is on.

 
Table 5: spill number
# event Spill 0-14 bit  
# pedestal flag 15 bit (if pedestal, bit on)


 
Table 6: event data format
# discription type comment
000 Length int  
001 Data ID int (station No # Monitor ID # Monitor No)
002 MONITOR DATA ID int  
003 Run # int  
004 Spill # int  
005 Event # int  
006 Triger type int (pedestal:1 or data:0 )
007 monitor Condition int (ON:1 or OFF:0)
008 CPU time(sec) int  
009 CPUtime(micro sec) int  
010      
: detector data (ADC etc)    
:      
???      
???+1 Delimiter int (-length)


next up previous contents
Next: RUN control Up: SoftWare Previous: Data stream

1999-03-19