*************************************************** * README for MUC plots shown at K2K collab.M * * summarised on 05/Jun./00 T. Inagaki * *************************************************** *-Analysed DATA sample-* DATA: 99-Jun. run: run1139-1276, 616441 spill 99-Nov. run: run2000-2218, 553175 spill 00-Jan. run: run2219-2332, 390810 spill 00-Feb. run: run2233-2416, 724764 spill 00-Mar. run; run2417-2525, 629244 spill Tracker version(131,0,2) of /k2k/00b, badch masked MC: 99-June config: cho 200kA (use latter MC with weight factor) 99-Nov. config: cho 250kA neut4.0, noise sim., hiteff=99% bunch struc. and beam axis were considered Tracker version(131,0,2) of /k2k/00b, badch NOT *-Event selection-* fiducial volume: 3mR*1.4m=312ton Fe detection efficiency: 0.3208 (99-June config.) 0.3300 (99-Nov. config.) *-List of figures-* 1) datasummary.ps analysed DATA summary, DATA/MC(cho,neut4) is also shown 2) skexpect.ps SK expect number calculation summary 3) syserror.ps systematic error for SK expect 4) syserror_conserv.ps conservative error estimation based on the neutrino spectrum uncertainty with 100% error below 1 GeV. ### This figure is NOT presented as the official plot. please contact to Inagaki ### 5) 99nov_data_stab.ps, etc.. (1point/every 12 hours) 99nov_data_stab2.ps, etc.. (1point/every 2 dayss) Event rate stability normalized by Target-CT(CT16)=5e+12ppp 6) 99nov_data_emu.ps, etc.. (DATA) 99nov_mc_emu.ps, etc.. (MC) muon energy spectrum graphs are normalized with its 'sum' 7) 99nov_data_thmu.ps, etc.. (DATA) 99nov_mc_thmu.ps, etc.. (MC) muon angle distribution from the z-axis 8) 99nov-00mar_datamc_emu.ps, etc.. muon energy spectrum with MC graphs are normalized with its 'sum' 9) 99nov-00mar_datamc_thmu.ps, etc.. muon angle distribution with MC 10) 99nov_data_profx.ps 99nov_data_profy.ps Vertex profile after acceptance/detector mass correction. The designed beam center is x=0cm, y=-15.8cm The fitted center have +-20cm precission as systematic error. 11) prof_stab.ps Corrected profile stability during 99-Nov. to 00-Mar. The designed beam center is x=0cm, y=-15.8cm The fitted center have +-20cm precission as systematic error. Each period corresponds; 1 99-Nov. run2000-2157 (10/29-11/9) 2 run2177-2204 (11/12-11/18) 3 run2207-2218 (11/19-11/24) 4 00-Jan. run2219-2242 ( 1/13- 1/18) 5 run2243-2277 ( 1/18- 1/23) 6 run2278-2332 ( 1/24- 1/29) 7 00-Feb. run2333-2351 ( 2/2 - 2/6) 8 run2353-2370 ( 2/9 - 1/14) 9 run2371-2399 ( 2/14- 2/20) 10 run2400-2416 ( 2/20- 2/26) 11 00-Mar. run2417-2450 ( 3/1 - 3/6) 12 run2452-2485 ( 3/6 - 3/13) 13 run2486-2514 ( 3/13- 3/19) 14 run2515-2525 ( 3/21- 3/23) *-Contact-* inagaki@neutrino.kek.jp phone:+298-64-5388 *-Fin.-*