    Message-ID: <Pine.LNX.3.96.1000815082301.23301E-100000@nurock.kek.jp>
    
    
    >  Could someone report the current status of Monte-Carlo of
    > the Scifi-detector and the related projects? I heard that
    > the electronics simulation part has been separated. Then,
    > you can start the more systematic study related to the 
    > possible sources of systematic errors such as IIT and elctronic
    > noises, changes of gains gain and so on.
    
    The simulation of the pixel clusters has been separated from the
    tracking of the particles. In principle one can now read in the
    same energy deposition and use different gains to estimate tracking
    efficiency systematic errors. I am attempting to do this (crudely
    at first) by looking at a DOPX=4 and DOPX=3 sample of the same MC
    sample. Since the algorithms are so different I would think that 
    the difference in the tracking efficiencies from these is a conservative
    estimate of the tracking efficiency systematic error due to gain
    differences. 
    